Back to How to Use

The Detailed Walkthrough

When & How to Discharge

A few small habits keep your AuricRefresh safe to store, safe around children and pets, and ready to use again at a moment's notice. Read this guide once and the procedure becomes second nature.

Why Discharging Matters

The device holds onto a small electrical charge after it is turned off. Discharging the device releases this energy safely. In most everyday situations, you do not need to discharge the device at all — but in two specific scenarios, discharging is essential.


Do I Need to Discharge After Every Single Use?

No. If your device stays set up in the same spot, it will naturally discharge itself over a few hours. However, you must discharge the device in the following scenarios:

  • Before storing: If you are packing the device away and need to touch the cables or terminals.
  • For household safety: If you leave the equipment out, discharging prevents accidental static shocks to children, pets, or others who might touch the device or the mesh while you are away.

For everyday back-to-back sessions in the same spot, there is no need to discharge between uses — the device takes care of itself.


How to Discharge Safely

Important: Please wait 5 minutes after unplugging the device before discharging. This allows the bulk of the energy to subside naturally, resulting in a much smaller, quieter static spark.
  1. Unplug the AC power cord from the wall outlet.
  2. Wait 5 minutes.
  3. Take the short 20-inch Discharge Cable. Hold it only by the plastic insulated handle.
  4. Touch the Black Plug to the Black Jack (Discharge A) on the front of the unit.
  5. While holding the black plug in place, tap the Red Plug to the Red Jack (Discharge B) on the back of the unit repeatedly until you no longer see or hear a small static spark.
Note: You do not need to fully insert the plugs; simply making metal-to-metal contact is enough.
Note: Never touch the Discharge Cable to the Output High Voltage terminal.

Clinic / Wellness Center Tip

If the device is being used continually by different people all day, do not discharge it between patients. This prevents unnecessary wear on the device.

Just ensure the next patient is seated on their insulated chair before their feet touch the mesh. The field connects the instant they make contact with the mesh, and disconnects the instant they lift their feet — so back-to-back sessions are perfectly safe without any discharging in between.


Quick Reference

Always Do

  • Wait 5 minutes after unplugging before discharging.
  • Hold the Discharge Cable only by its plastic insulated handle.
  • Use the Black Plug on the front Black Jack (Discharge A).
  • Tap the Red Plug on the back Red Jack (Discharge B) until no spark remains.

Never Do

  • Touch the Discharge Cable to the Output High Voltage terminal.
  • Hold the Discharge Cable anywhere except the plastic insulated handle.
  • Discharge immediately after unplugging — always wait 5 minutes.
  • Discharge between every patient in a busy clinic setting.

Still Have a Question About Discharging?

We're happy to walk you through the procedure — email us anytime, and we typically respond within minutes to a few hours.

[email protected]

Email Us

Ready to Step Into the Field?

Simple to use. Effortless to own. A lifetime of healing in your own home.

Order Your AuricRefresh Today